Honeywell MP516 Unit Vent Damper Operators.
For MP516 Unit Vent Damper Operators.
| ORDERING INFORMATION |
| ORDER # |
DESCRIPTION |
| HDK516 |
For MP516B,C |
| HDD516 |
For MP516A |
Honeywell LP916 Repair Kit
Kit contains: plate, gaskets and filters to repair LP916 unit mounted pneumatic stats.
| ORDERING INFORMATION |
| ORDER # |
DESCRIPTION |
| HCK916 |
LP916 Repair Kit |
Honeywell RP908A,B Receiver Controller Repair Kit
Complete kit for repairing the old style RP908A & B Receiver-Controllers.
Kit contains: body gasket, O-rings, restrictors, screens filters, washers.
| ORDERING INFORMATION |
| ORDER # |
DESCRIPTION |
| HCK908 |
RP908 Repair Kit |
Honeywell PP902A,B Filter Station Repair Kit
Kit contains: screw carriage, O-rings, filter cartridge and lubricant.
| ORDERING INFORMATION |
| ORDER # |
DESCRIPTION |
| HFK902 |
Filter Station Repair Kit |
Honeywell Universal Electronic Valve Operator
One Direct-Coupled Operator For All Electric/ Electronic Signals—No Extra Linkages Needed!
The ML6984, ML7984 are self-contained, self-adjusting, motorized actuator that mounts directly onto 1/2'' to 3'' threaded V5011 or V5013 valves. It’s ideal for replacing MP953 pneumatic actuators when automating.
Field Selectable Features:
- Electronic or Resistance (series 70 or 90) Control
- Direct/Reverse Actuation
- 24Vac/dc Power Supply
- SPDT End Switch
- Replaces All ML784 and ML984 Actuators
- Pulse Width Modulating
| Valve Closeoff Ratings |
| Up to 1'' |
150# |
| 1-1/4'' |
145# |
| 1-1/2'' |
91# |
| 2'' |
47# |
| 2-1/2'' |
32# |
| 3'' |
19# |
Stroke: 3/4"
Honeywell V5011 & V5013 Valve Repair Parts
For individual repair parts on Honeywell older or industrial valves, we will FAX you a parts breakdown so you can select the items you need.

| V5011, V5013 REPACK KITS |
| KIT NUMBER |
PIPE SIZE |
STEM SIZE |
| V5011C & G | V5011/13A & F |
| HPK114 | HPK944 |
1/2'' to 1-1/4'' |
1/4'' |
| HPK115 | HPK954 |
1-1/2'' to 3'' |
3/8'' |
| HPK116 | HPK116 |
4'' to 6'' |
1/2'' |
* Items indicated with an asterisk are included in each kit.
Honeywell Peumatic Valve Repair parts
These replacement kits contain a completely assembled top and stem assembly, valve seat and all fittings necessary to connect either copper or plastic tubing. Only the existing valve body must be reused. Rebuilding can be done without removing the valve body from the line. Replacement top assemblies contain the metal top, fitting and diaphragm.


Honeywell VP501, VP525, VP531 Valve Repair Parts
| VP501, VP525 PARTS |
| ORDER # |
DESCRIPTION |
| HVK501 |
1/2", 2.0 Cv Rebuild Kit |
| HVK502 |
1/2", 3.0 Cv Rebuild Kit |
| HVK503 |
3/4", 3.0 Cv Rebuild Kit |
| HVK504 |
3/4", 5.0 Cv Rebuild Kit |
| HVD525 |
VP525 Repl. Diaphragm |
| HVT525 |
Repl. Top Assembly |
Honeywell VP526, VP527 Valve Repair Parts
| ORDERING INFORMATION |
| ORDER # |
DESCRIPTION |
| HVD526 |
Diaphragm for VP526, 527 |
| HPK526 |
Repack Kit for VP526, 527 |
| 14003102-001 |
Replacement Top Assembly |
| HVK527-1 |
VP527 Rebuild Kit – 0.4 or 0.6 Cv |
| HVK527-2 |
VP527 Rebuild Kit – 1.0 or 1.6 Cv |
Honeywell VP512 Repair Parts
| VP512 REPAIR PARTS |
| ORDER # |
DESCRIPTION |
| HVD531 |
Neoprene Diaphragm (Black) |
| HVD522 |
Silicone Diaphragm (White) |
| HVP512 |
1/4" Valve Packing (3 required for each) |
| HVK511 |
Rebuild Kit for 3/4" to 1-1/4", 6.3 or 10 Cv |
| HVK512 |
Rebuild Kit for 1/2" to 3/4", 4.0 Cv or under |
| 14003294-002 |
Steam Repack Kit |
| 14003294-004 |
Water Repack Kit |
| 312817AA |
Actuator Assembly |
Honeywell Unit Ventilator Valve Assemblies
A normally open, single seated, straight through pneumatic valve used for proportional control of steam or hot water in unit ventilator applications.
Honeywell Pneumatic Radiator Valve Assemblies
Normally open, single seated pneumatic radiator valve with straight through or angle body construction provides proportional control of two-pipe, hot water or steam systems.
Hneywell Unit Ventilator Valve Assemblies
Normally open, single seated valve provides proportional control of steam or hot or cold water in terminal units.
| ORDERING INFORMATION |
| ORDER # |
Cv |
RANGE |
PIPE SIZE |
PATTERN |
| VP531C1000 |
1.6 |
2-5# use 315913 spring for 3-10# range |
1/2'' NPT |
N.O. Straight thru |
| VP531C1018 |
2.6 |
3/4" NPT |
| VP531C1026 |
3.3 |
| VP531C1034 |
1.6 |
5/8'' O.D. Solder |
N.O. Straight thru 1/2'' nominal |
| VP531C1042 |
2.6 |
7/8" O.D. Solder |
N.O. Straight thru 3/4'' nominal |
| VP531C1059 |
3.3 |

Honeywell Pneumatic Valve Actuators
These pneumatic actuators operate V5011 and V5013 valve assemblies.
They provide proportional control of steam or hot and cold liquids in HVAC systems.

Honeywell MP953 Replacement Diaphragms
Old style 5" diaphragms have a flat edge around the circumference while new style diaphragms have a beaded roll edge. They are not interchangeable.
Silicone diaphragms are used in operators requiring higher temperature ratings. They are interchangeable with neoprene diaphragms of the same style and size.
| ORDERING INFORMATION |
| Neoprene ORDER # | Silicone ORDER # |
DESCRIPTION |
| HVD521 | 313745 |
5" New Style Diaphragm |
| HVD532 | 310668 |
5" Old Style Diaphragm |
| HVD533 | 314153 |
8" Diaphragm |
| HVD534 | — |
13" Diaphragm |
| HVD535 | — |
R.A. Diaphragm and Seal Kit for MP953B,D,F |