Loading...

Honeywell Thermostatic Valves

Honeywell Thermostatic Mixing Valves

The Honeywell Sparcomix AM-1 series accurately adjusts, maintains and limits the hot water temperature to a desired setting selected by the user. In domestic water applications it offers anti-scald, anti-chill protection and saves money. The installation of a Honeywell AM-1 mixing valve on an 80 gallon hot water heater increases the usable hot water to 120 gallons by running the water heater at a higher temperature and mixing it to a safe usable temperature. In heating applications it provides comfort and protects the equipment.

Features:

  • Dual purpose mixing or diverting valves
  • Constant water temperature under changing operating conditions
  • Reliable performance at minimum flow of 0.5 gpm
  • Proportional valve (simultaneous control of hot and cold water)
  • Energy savings through lower supply temperatures
  • Anti-scald, anti-chill thermal shock protection
  • Temperature limit at any point
  • Nickel-plated brass/bronze construction, EPDM O-rings
  • All bronze proportioning shuttle
  • Straight through design (hot and cold at the same level)
  • Max. press. 150 psi (1034 kPa), temp. 212 F (100 C)
  • Designed for easy maintenance and element replacement
  • Teflon® coated to prevent mineral build-up and extend life
  • Tamper evident design
  • Valve trapping not required
  • Approvals: ASSE 1016 and ASSE 1017. Not rated for point of use under ASSE 1070.
ORDERING INFORMATION
ORDER # SIZE CONNECTION RANGE (˚F)
AM100-1 1/2" NPT 100-145
AM100-US-1 Union Sweat
AM100-UT-1 Union NPT
AM100B-1 NPT 60-100


AM100-C-1 NPT 80-120
AM100C-US-1 Union Sweat
AM100C-UT-1 Union NPT
AM101-1 3/4" NPT 100-145
AM101-US-1 Union Sweat
AM101-UT-1 Union NPT
AM101C-1 NPT 80-120
AM101C-US-1 Union Sweat
AM101C-UT-1 Union NPT
AM101C-UCPVC-1 Union PVC


Honeywell Thermostatic Radiator Valve Controllers

Thermostatic Radiator Valves …

directly replace manual valves on hot water and steam radiators and convectors. They provide automatic temperature control of each unit, space or zone and require no electricity or wiring. They are constructed to match the exact dimensions of most manual radiator valves. Many supply pipes come straight through the floor or through the wall, failing to give you sufficient room to install a replacement.

T104A
Direct-mount sensor and setpoint dial. Includes built-in limit stops. Not for use in enclosure.

 

 


 

T104F
Valve mounted setpoint with 6.5' remote sensor.

 

 


 

T104B
Wall mounted sensor and setpoint dial connected to valve actuator by a 6'8" capillary.

 

 


 

T104V
Vandal-resistant direct-mount sensor and dial. Setpoint under locking cover. Factory set at 68°F.

 

 


 

T104C
Remote sensor and remote set dial. Both have separate 4.5' capillaries.

 

 

ORDERING INFORMATION
HIGH CAPACITY VALVE ACTUATORS
ORDER # DESCRIPTION
T104A1040 Direct Mount Sensor/Setpoint
T104B1038 Remote 6.5' Sensor/Setpoint
T104B1046 Remote 16' Sensor/Setpoint
T104C1036 Remote 4.5' Sensor, 4.5' Setpoint
T104F1512 Remote 6.5' Sensor, Direct Mount Setpoint
T104V1422 Vandal proof Direct Mount Sensor/Setpoint Factory Set at 68°F

Use these actuators with High Capacity V110 valves only.



Honeywell Thermostatic Radiator Valves

One of the simplest forms of temperature controls, radiator valves install quickly. They directly replace the manual shutoff valves on heating radiators. They are available in a variety of valve bodies and sensor configurations, so you can pick the model easiest to install.


ORDERING INFORMATION
MEDIUM CAPACITY VALVE BODIES
ORDER # DESCRIPTION CAPACITY
V2040ASL15 1/2'' Horizontal Angle 2.5 Cv Water - 59 MBH Steam
V2040ASL20 3/4'' Horizontal Angle 2.7 Cv Water - 64 MBH Steam
V2040ASL25 1'' Horizontal Angle 2.7 Cv Water - 70 MBH Steam
V2040DSL15 1/2'' Straight Body 2.5 Cv Water - 59 MBH Steam
V2040DSL20 3/4'' Straight Body 2.7 Cv Water - 64 MBH Steam
V2040DSL25 1'' Straight Body 2.7 Cv Water - 70 MBH Steam

TYPICAL INSTALLATIONS

THERMOSTATIC ACTUATORS
ORDER # DESCRIPTION
T1002W0NA Direct Mount Sensor/Setpoint
T100B1035 Remote 6.5' Combined Sensor/Setpoint
T100B1043 Remote 16' Combined Sensor/Setpoint
T100C1026 Remote 4.5' Sensor, 4.5' Setpoint
T100F1395 Remote 6' 8" Sensor, Integral Setpoint
T100M2056 Direct Mount Sensor/ Setpoint - Tamperproof


Braukmann Thermostatic Radiator Valves

Fastest Energy Payback! • Easy To Install • No Wiring
Compared with other energy-saving alternatives, thermostatic radiator valves represent one of the most COST EFFECTIVE ways to reduce total heating bills! A recent study of energy savings by several federal institutions concluded that thermostatic radiator valves are the best energy investment per BTU currently available.

  • Valve seat disc, which is made of resilient material, ensures tight shutoff on steam or hot water systems.
  • Nickel-plated cast brass body with working parts in cartridge insert for ease of service.
  • Requires no electrical connections.
  • All working parts are replaceable while valve remains in service, in-line, under pressure.
  • Valve normally open without control mounted.
ORDERING INFORMATION
ORDER # SIZE STYLE
V110D1000 1/2'' NPT Straight
V110D1008 3/4'' NPT
V110D1016 1'' NPT
V110D1024 1-1/4'' NPT
V110D5001 1/2'' Sweat
V110D5009 3/4'' Sweat
V110D5017 1'' Sweat
V110E1004 1/2'' NPT Angle
V110E1012 3/4'' NPT
V110E1020 1'' NPT
V110E1028 1-1/4'' NPT
V110E5005 1/2'' Sweat
V110E5013 3/4'' Sweat
V110F1002 1/2'' NPT Horizontal Angle
V110F1010 3/4'' NPT
V110F1018 1'' NPT
V110F1026 1-1/4'' NPT
V110F5003 1/2'' Sweat
V110F5011 3/4'' Sweat

VALVE CAPACITIES
SIZE WATER STEAM
1/2" 4.6 Cv 127 MBH
3/4" 5.8 Cv 162 MBH
1" 7.0 Cv 193 MBH
1-1/4"

MBH = 1000 BTU / hr

Pressure Ratings:

150# Water, 15# Steam

NOTE: Horizontal angle valves are specifically engineered for direct-mounted sensors to keep them away from radiated heat.


Honeywell Thermostatic Radiator Valves for One-Pipe Steam Systems

This control regulates the room temperature of one-pipe, low pressure steam radiators or convectors. It directly replaces the 1/8'' vent valve and controls the temperature by venting the radiator on a call for heat. When the temperature is satisfied, the valve closes. The resulting air build-up restricts steam flow. They are usually mounted with a direct-mount thermostatic head. T100 remote operators can also be used on the Honeywell or Braukmann valve bodies.

ORDERING INFORMATION
HONEYWELL DESCRIPTION
V2042HSL10 1-pipe Valve Body 1/8''MPT
SA123A1002 Steam/Air Vent
T100A1028 Direct-Mount Control
T100B1035 6'8'' Remote Sensor/Setpoint
V2043HSL10 1-pipe Kit: T5086, V5086, Vent

Maximum Pressure: 15 psi
Vent Connection:
1/16'' MPT
Position:
Normally Open

TYPICAL INSTALLATION


Honeywell T104/V110 THERMOSTATIC RADIATOR VALVE ACCESSORIES AND REPAIR PARTS
ORDER # DESCRIPTION USED WITH
2428300 Replacement Seat Disc V110
CA110C1007 Replacement Cartridge V110D,E,F
203225 Remote Bulb Guard T104F1512
A104F1007 Range Limit Pins T104A,F
G111B1053 Remote Bulb Guard T104C
MT110C1011 Cartridge Tool V110
MT110D1019 Cartridge Socket V110D,E,F
No data found

Close

Search:

Authorized distributor of more than 200,000 HVAC
parts & controls.


Join Our Mailing List
Email:
 
Follow us on LinkedIn Follow us on FaceBook Follow us on Twitter

When you get a bladder infection, urine trouble.I changed my i Pod's name to Titanic.  It's syncing now.What does a clock do when it's hungry?  It goes back four seconds.I used to be a banker, but then I lost interest.Broken pencils are pointless.I dropped out of communism class because of lousy Marx.What do you call a dinosaur with an extensive vocabulary?  A thesaurus.When chemists die; they Barium.England has no kidney bank, but it does have a Liverpool.All the toilets in New York's police stations have been stolen.  Police have nothing to go on.Jokes about German sausage are the wurst.I know a guy who's addicted to brake fluid.  But he says he can stop any time.I got a job at a bakery because I kneaded dough.Cartoonist found dead in home.  Details are sketchy.How does Moses make his tea?  Hebrews it.I stayed up all night to see where the sun went.  Then it dawned on me.This girl said she recognized me from the vegetarian club, but I'd never met herbivore.I'm reading a book about anti-gravity and I can't put it down.I did a theatrical performance about puns.  It was a play on words.They told me I had type A blood, but it was a Type-O.Why were the Indians here first?  They had reservations.Class trip to the Coca-Cola factory.  I hope there's no pop quiz .Energizer Bunny arrested.  Charged with battery.I didn't like my beard at first.  Then it grew on me.Did you hear about the cross eyed teacher who lost her job because she couldn't control her pupils?