Honeywell Electronic HVAC Controllers

Honeywell T775 Electronic Standalone Controllers

The newly redesigned T775 "2000" series of electronic standalone controllers incorporates many new features to make it the most economic and flexible controller available. All T775’s can be powered with low or line voltage (24, 120 or 240 VAC).

  • Easy-To-Use Graphical Interface
  • Internal Time Clock Scheduler
  • Up to Two Independent Modulating Outputs (Selectable: 4-20 mA, 0-10 Vdc, 2-10 Vdc and Series 90)
  • NEMA 4X Enclosure Option
  • Modulating High Or Low Limit Control
  • Optional Configurable Integral and Derivative Times
  • Reset Models With Simplified Setup
  • Configurable Minimum Off Time
  • Sensor Calibration

ORDERING INFORMATION
Order # Description Relays Analog Outputs Floating Outputs Sensor Inputs Sensors Included
T775A2009 Standard 1 SPDT None None 1 1
T775B2032 2 SPDT 1 2
T775B2040 4 SPDT 2
T775M2006 Modulating None 2 None
T775M2022 Modulating-NEMA 4X 2 SPDT
T775R2035 With Reset Option None 1 2
T775R2027 With Reset Option 2 None
More models are available

T775 Accessories

There are many remote temperature sensors that are compatible with the T775 Series 2000. The T775 accepts 1,097 Ohms PTC at 77°F.

ORDERING INFORMATION
ORDER # DESCRIPTION
50021579-001 Standard sensor(s) included w/T775 (except T775U and NEMA 4x models)
T775-SENS-WR Water resistant sensor(s) w/6" leads (packaged w/NEMA 4X models)
T775-SENS-WT Watertight sensor w/6 foot leads
C7031D2003 5" immersion sensor w/wiring box
50001774-001 Immersion well for C7031D2003
C7031J2009 12 foot averaging duct sensor w/wiring box
C7046D1008 8" duct probe w/mounting flange
C7100D1001 12" fast response, duct averaging sensor w/flange
C7130B1009 Room mount sensor

Honeywell T775 Universal Model

The 775U Universal Model provides setup for configuring control of:

-Pressure
-Humidity
-Temperature
-Or any 0-10 Vdc or 4-20 mA input

The input range of this model is completely scaleable!

You select which units you are measuring and displaying (inches W.C., PSI, Pa, kPa, %RH, o F or o C or just generic %).

This is the first commercial controller with this capability. Previously, you had to use an Industrial Single Loop Controller at three times the cost to control any other application other than temperature or %RH.

Control humidity within % displayed, or pressure within inches W.C. or PSI. Outputs include 2 modulating and 2 relay outputs that can each have its own setpoint.

The T775P Special Boiler Model offers features like dedicated pump output, staging for up to 12 relays, digital output alarm, pump exercise, pump pre-purge and post-purge, warm weather shut-down, built-in scheduler, displayed run time and more.

The T775L Sequencer Model has 4 stages, plus add up to 2 optional 4-stage expansion modules for 8, or 12 stage operation. Control these relays anyway you like with one or two set points: 4-heat, 2-cool; 6 cool, 4-heat; whatever you need.

ORDERING INFORMATION
ORDER # DESCRIPTION RELAYS AO's DO's Dedicated Pump Output SENSOR INPUTS SENSORS INCLUDED Expand- able OUTPUT RESET
T775P2003 Special Boiler w/Reset 1 SPDT None 1 Y 3 3 Y Y
T775L2007 Stage Sequencer w/reset option 4 SPDT* None N 1 1 Y Y
T775U2006 Universal Humidity, Pressure, etc. 2 SPDT 2 2** 2** N Y
T775S2008 Relay Expansion Module 4 SPDT Use with T775P or T775L

* 4 or 8 more relays possible by adding one or two T775S2008 4-relay Expansion Module(s)
** Up to 2 independent non-sequenced relays are also available

No data found

Close

Search:

Authorized distributor of more than 200,000 HVAC
parts & controls.


Join Our Mailing List
Email:
 
Follow us on LinkedIn Follow us on FaceBook Follow us on Twitter

When you get a bladder infection, urine trouble.I changed my i Pod's name to Titanic.  It's syncing now.What does a clock do when it's hungry?  It goes back four seconds.I used to be a banker, but then I lost interest.Broken pencils are pointless.I dropped out of communism class because of lousy Marx.What do you call a dinosaur with an extensive vocabulary?  A thesaurus.When chemists die; they Barium.England has no kidney bank, but it does have a Liverpool.All the toilets in New York's police stations have been stolen.  Police have nothing to go on.Jokes about German sausage are the wurst.I know a guy who's addicted to brake fluid.  But he says he can stop any time.I got a job at a bakery because I kneaded dough.Cartoonist found dead in home.  Details are sketchy.How does Moses make his tea?  Hebrews it.I stayed up all night to see where the sun went.  Then it dawned on me.This girl said she recognized me from the vegetarian club, but I'd never met herbivore.I'm reading a book about anti-gravity and I can't put it down.I did a theatrical performance about puns.  It was a play on words.They told me I had type A blood, but it was a Type-O.Why were the Indians here first?  They had reservations.Class trip to the Coca-Cola factory.  I hope there's no pop quiz .Energizer Bunny arrested.  Charged with battery.I didn't like my beard at first.  Then it grew on me.Did you hear about the cross eyed teacher who lost her job because she couldn't control her pupils?